Docs » Uptime Tests for port and HTTP » Set up an Uptime test

Set up an Uptime test ๐Ÿ”—

An Uptime test lets you make a request to a specified URL or port address and monitor its response time and response code. Uptime tests record three metrics from each run: response time, DNS time, and time to first byte.

Decide whether you want to set up an HTTP Uptime test or Port Uptime test, and then follow the steps below to set up your test. To learn more about the types of Uptime tests, see Uptime Tests for port and HTTP.

Note

If the site or application you are monitoring uses allow lists or block lists for visitors or an analytics tool to measure traffic, check that it is configured to accommodate traffic from Splunk Synthetic Monitoring. See Get your site ready to run synthetic tests for instructions.

Configure an HTTP Uptime test ๐Ÿ”—

Follow these steps to set up a HTTP Uptime test:

  1. From the landing page of Splunk Observability Cloud, navigate to Splunk Synthetic Monitoring.

  2. In the Tests section, select Add New Test and select Uptime Test from the drop-down list. This opens the New Uptime Test page.

  3. Make sure the HTTP tab is selected.

  4. In the Name field, enter a name for your test. You will use this name to identify data from the test in your alerts and reports.

  5. In the URL field, paste the URL for the page you want to test, including http or https.

  6. As you build your test, you can use Try now to check that the configuration of your test is valid. Run results arenโ€™t stored. For more, see Validate your test configuration with try now.

  7. (Optional) Turn on automatic test retry in the event a test initially fails.

Configure a Port Uptime test ๐Ÿ”—

Follow these steps to set up a Port Uptime test:

  1. From the landing page of Splunk Observability Cloud, navigate to Splunk Synthetic Monitoring.

  2. In the Tests section, select Add New Test and select Uptime Test from the drop-down list. This opens the New Uptime Test page.

  3. Select the Port tab.

  4. In the Name field, enter a name for your test. You will use this name to identify data from the test in your alerts and reports.

  5. In the Address field, use the drop-down list to indicate whether the port you are monitoring follows TCP or UDP protocol. Enter the host and port addresses.

Customize your test details ๐Ÿ”—

Use these steps to customize your test configuration and finish creating your test:

  1. In the Locations field, enter the locations from which you want to test the URL. You can select one or multiple locations.

  2. In the Device Type field, use the list to select the device from which youโ€™d like to conduct the test.

  3. In the Frequency field, select your desired test frequency from the list.

  4. (Optional) Use the Round Robin selector to switch between options: enabling Round Robin means your test cycles through your selected locations one at a time, while disabling Round Robin runs the test from all selected locations concurrently at your selected frequency.

  5. If you want to receive alerts from this test, select + Create detector to set up a detector on the test. Use the dialog box to customize your detector.

  6. Select Submit. This redirects you to the Test History page for your new test. If youโ€™ve just created the test, allow at least one test frequency interval for your test to begin collecting synthetic data.

  7. (Optional) Select Edit test or the three-dot Actions menu in the row for your test to edit, pause, duplicate, or delete this test.

See also ๐Ÿ”—

View your Uptime test ๐Ÿ”—

Now that you created and saved a test, check whether itโ€™s collecting data as expected:

  1. From the Tests list, select the three-dot Actions menu and select Play arrow icon to manually trigger a live run of the test, or wait for at least one duration of the test frequency you set so that the test has time to run and collect data.

  2. Select the test youโ€™re interested in to open the Test History view, where you can view visualizations of recent test results and metrics.

Interpret your Uptime test results ๐Ÿ”—

See Interpret Uptime test results for an overview of run-level Uptime test results.

Advanced settings for uptime tests ๐Ÿ”—

There are many reasons why you might want to configure advanced settings for your synthetics tests. Here are a few:

  • Accessing a site with a modal that appears randomly and interrupts the flow of the test. For example, a marketing modal might prompt a user to sign up for a rewards program. To circumvent this issue you can set a cookie to stop the popup modal from appearing and interfering with your test.

  • Running a test on a site that requires users to log in to access the site.

  • Specifying the type of device on which you want to run your test by setting the User-Agent header on requests.

  • Testing out a CDN. For example, you might want to load the HTML page in the browser, but rewrite the hosts for some or all requests to a new host.

  • Filtering out requests from analytics on the back end by sending a specific header in the requests.

  • Running a test on a pre-production site that has a self-signed certificate.

Custom properties ๐Ÿ”—

Add custom properties in the test creation page in advanced settings. Use key-value pairs to create custom properties to filter and group dashboards, charts, and create alerts. A list of suggested custom properties is available for each test based on the tags associated with your test. For example: env:test, role:developer, product:rum. When you have multiple key-value pairs the logic is AND among the results. So in this case, the results show all tests for the RUM product with a developer role in the environment test.

This image shows two custom property key value pairs, env:prod and role:developer.

Custom properties are single-valued and donโ€™t support multiple values, like region:eu, us. For each test, you can only use one and unique key. For example, you can have env1:test and env:test in the same test, but you canโ€™t have env:test, and env:prod.

Key requirements:

  • Keys must start with an uppercase or lowercase letter. Keys canโ€™t start with special characters or numbers.

  • The remainder of the key can contain letters, numbers, underscores and hyphens.

  • Keys canโ€™t be named test_id or test.

  • Key size canโ€™t exceed 128 characters.

See, Custom properties.

Auto-retry ๐Ÿ”—

Run a test again automatically if it fails without any user intervention. Itโ€™s a best practice to turn on auto-retry to reduce unnecessary failures from temporary interruptions like a network issue, timeouts, or other issues. Auto-retry runs do not impact subscription usage, only the completed run result counts towards your subscription usage. Auto-retry requires at least runner version 0.9.29.

Select an HTTP method ๐Ÿ”—

Select an HTTP method and add a payload.

Set custom headers ๐Ÿ”—

Specify custom headers to send with each request. For example, you can add a header in your request to filter out requests from analytics on the back end by sending a specific header in the requests. You can also use custom headers to set cookies.

Activate SSL/TLS validation ๐Ÿ”—

When activated, this feature is used to enforce the validation of expired, invalid hostname, or untrusted issuer on SSL/TLS certificates. When testing pre-production environments that have self-signed or invalid certificates, itโ€™s best to leave this feature deactivated.

Add assertions ๐Ÿ”—

You can make an assertion on two values. Add two parameters along with the comparison that you would like to perform between the two. There are three types of comparisons: string, numeric, and regular expression. For string and numeric comparisons, values are coerced to the comparison type before the comparison is made. For a regular expression comparison, the first parameter is a string and the second parameter is a regular expression. An assertion step fails if the assertion is false when the step runs.

  • Use matches to compare the string to a regex pattern.

  • Use contains checks for a substring.

Example ๐Ÿ”—

For an example, see Scenario: Monitor the performance of a user-facing application.

This page was last updated on Dec 09, 2024.