Splunk Edge Hub release notes
Thank you for your interest in the the Splunk Edge Hub. You can collect sensor data and stream it into a Splunk Cloud platform instance. To get started, see the following documentation:
- Splunk Edge Hub Overview
- Get started with the Splunk Edge Hub Software
- Download the Splunk Edge Hub Mobile app
Splunk Edge Hub Software is supported with Victoria and Classic Experience Splunk Cloud Platform and Splunk Enterprise deployments version 9.0 or higher.
Minimum version compatibility
The following table provides the minimum version requirements to support the latest features in the Splunk Edge Hub Software, Splunk Edge Mobile app, and Splunk App for Edge Hub and AR:
Splunk Edge Hub Software | Splunk Edge Mobile app | Splunk App for Edge Hub and AR |
---|---|---|
1.4.2 | 1.7.0 | 4.3.1 |
What's New
Splunk Edge Hub Software version 1.4.2 now supports the following capabilities:
- Support for devices that use the Modbus protocol. See Configure Splunk Edge Hub Software to communicate with electronic devices using the Modbus protocol to learn how to configure the Splunk Edge Hub Software to use the Modbus protocol.
- Changes are instantly applied to the Splunk Edge Hub Software when modifying the HTTP Event Collector (HEC) and index settings.
See the Splunk Edge Mobile release notes to learn more about the mobile app updates.
See the Splunk App for Edge Hub and AR release notes to learn more about the web app updates.
Fixed issues
We fixed the following issue in this version:
- The Disk Memory Used (%) metric is not available in the Splunk Edge Hub Performance dashboard.
Known issues
The following are known issues in this version of Splunk Edge Hub Software:
- Splunk Edge Hubs cannot be registered using Splunk Cloud Platform version 9.0.2209.2. Use Splunk Cloud platform version 9.0.2208.4 instead.
- During Advanced Registration, the Splunk Edge Mobile app gives the error, "A server with the specified hostname could not be found."
- Workaround: Repeat registration steps until you get the message "Continue on the Hub". Complete steps on the Splunk Edge Hub screen.
- When creating topic rules in the Edge Hub Advanced Settings MQTT tab, the page displays an error if you attempt to create a metric, timestamp, or dimension without saving the topic rule first.
- The Splunk Edge Hub sends excess data points for a provided sampling frequency.