Modular inputs configuration
This topic describes several ways to define configuration for modular inputs. It includes the following:
- How to create and edit the
inputs.conf.spec
file for modular inputs. - Configuration layering for modular inputs
- Specifying permissions to access modular input apps
Create a modular input spec file
Specific locations are required for all spec files. For modular inputs, the spec file is located in a README
directory of the app implementing the modular input.
$SPLUNK_HOME/etc/apps/<myapp>/README/inputs.conf.spec
The location of script referenced in the spec file is here:
$SPLUNK_HOME/etc/apps/<myapp>/bin/<myscript>
Structure of a spec file
Splunk Enterprise provides numerous spec files that it uses to configure and access a Splunk Enterprise server. These default spec files are heavily commented and include examples on how to configure Splunk Enterprise.
However, the structure of a spec file is quite basic, it only requires the following elements:
- stanza header (one or more)
- param values (one or more for each stanza)
The following shows a minimal inputs.conf.spec file. In this file, the values for the parameters are not present. These are not required. If present, Splunk Enterprise ignores them. Additionally, the <name> element in the stanza header is ignored.
Sample inputs.conf.spec file
[myscript://<name>]
param1 =
Writing valid spec files
Here are some things to keep in mind when writing spec files:
- The
inputs.conf.spec
spec file must be at the following location:
$SPLUNK_HOME/etc/apps/<app_name>/README/
- The following regex defines valid identifiers for the scheme name (the name before the
://
) and for parameters:
[0-9a-zA-Z][0-9a-zA-Z_-]*
- Avoid name collision with built-in scheme names. Do not use any of the following as scheme names for your modular inputs:
- batch
- fifo
- monitor
- script
- splunktcp
- tcp
- udp
- Some parameters are always implicitly defined. Specifying any of the following parameters for your modular inputs has no effect. However, you could specify these to help clarify the usage:
- source
- sourcetype
- host
- index
- disabled
- interval
- persistentQueue
- persistentQueueSize
- queueSize
- Modular inputs can only be defined once. Subsequent definitions (a new scheme stanza) and their parameters are ignored.
- A scheme must define at least one parameter. Duplicate parameters are ignored.
- The stanza definition and their parameters must start at the beginning of the line.
Spec file example
Here is the spec file for the Amazon S3 example.
S3 inputs.conf.spec file
[s3://<name>] key_id = <value> * This is Amazon key ID. secret_key = <value> * This is the secret key.
Configuration layering for modular inputs
As described in Configuration file precedence in the Admin manual, Splunk Enterprise uses configuration layering across inputs.conf
files in your system. Configuration for modular inputs contrasts with how configuration generally works. Typically a configuration stanza only inherits from the global default configuration.
For modular inputs configuration, each modular input scheme gets a separate default stanza in inputs.conf
. After Splunk Enterprise layers the configurations, the configuration stanza for a modular input (myScheme://aaa
) inherits values from the scheme default configuration. A modular input can inherit the values for index and host from the default
stanza, but the scheme default configuration can override these values.
For example, consider the following inputs.conf
files in a system:
Global default
.../etc/system/local/inputs.conf
[default] . . . index = default host = myHost
Scheme default
.../etc/apps/myApp/default/inputs.conf
[myScheme] host = myOtherHost param1 = p1
Configuration stanza
.../etc/apps/search/local/inputs.conf
[myScheme://aaa] param2 = p2
Here is how layered configuration is built:
- Apply the values for index and host from the global default.
In a typical installation the values for index and host from the global default configuration apply to all inputs. Other values in the global default configuration do not apply to modular inputs. - Apply values from scheme default, overriding any values previously set.
- Apply values from configuration stanza, overriding any values previously set.
The layered outcome of the above configuration example is:
Layered configuration example
[myScheme://aaa]
index = default #from Global default
host = myHost #from Global default, overridden by Scheme default
host = myOtherHost #from Scheme default
param1 = p1 #from Scheme default
param2 = p2 #from Configuration stanza
Interval parameter
Use the interval parameter to schedule and monitor scripts. The interval parameter specifies how long a script waits before it restarts.
The interval parameter is useful for a script that performs a task periodically. The script performs a specific task and then exits. The interval parameter specifies when the script restarts to perform the task again.
The interval parameter is also useful to ensure that a script restarts, even if a previous instance of the script exits unexpectedly.
Entering an empty value for interval results in a script only being executed on start and/or endpoint reload (on edit).
single script instance per input stanza mode
For single script instance per input stanza mode, each stanza can specify its own interval parameter.
single script instance mode
For single script instance mode, Splunk Enterprise reads the interval setting from the scheme default stanza only. If interval is set under a specific input stanza, that value is ignored.
For single script instance mode, interval cannot be an endpoint argument, even if it is specified in inputs.conf.spec. You cannot modify the interval value for single script instance mode using the endpoint.
Persistent queues
You can configure persistent queues with modular inputs. You can use persistent queues with modular inputs much as you do with TCP, UDP, FIFO, and scripted inputs, as described in Use persistent queues to help prevent data loss.
You configure persistent queues for modular inputs much as you do with other inputs. There are differences depending on the type of modular input.
single script instance per input stanza mode
In this mode, a script is spawned for each inputs stanza. Because each script produces its own stream, it can have its own persistent queue. The correct way to configure a persistent queue is to put the persistent queue parameters under each inputs stanza:
[foobar://aaa]
param1 = 1234
param2 = qwerty
queueSize = 50KB
persistentQueueSize = 100MB
Another way to configure a persistent queue is to put queueSize and persistentQueueSize under the scheme default stanza (in this example, [foobar]). All input stanzas inherit these params and result in the creation of a separate persistent queue for each input stanza.
single script instance mode
In this mode, there is only one stream of data that services all inputs stanzas for that modular input. The only valid way to configure the persistent queue is to put the settings under the scheme default stanza. Placing it under a specific input stanza has no effect.
[foobar]
queueSize = 50KB
persistentQueueSize = 100MB
Persistent queue location
Persistent queue files are in the same directory location as scripted inputs:
$SPLUNK_HOME/var/run/splunk/exec/<encoded path>
<encoded path>
derives from the inputs stanza (for single script instance per input stanza mode) or the scheme name (for single script instance mode).
Specify permissions for modular input scripts
Read permission for modular input scripts is controlled by the list_inputs
capability. This capability also controls reading of other input endpoints.
By default, the admin_all_objects
capability controls create and edit permissions for modular inputs. However, you have the option to create a capability that customizes edit and create permissions for any specific modular input scheme. If the custom capability for a modular input is present, the custom capability is applied rather than the default admin_all_objects
capability.
The custom capability for modular inputs takes the following form:
edit_modinput_myscheme
After creating the capability for a modular input, enable it for one or more user roles.
- Caution: Make sure you assign one or more roles for the capability
edit_modinput_myscheme
, otherwise no one can create or edit modular inputs for that scheme.
To create a custom capability and assign roles edit the authorize.conf
configuration file. For example, to create a custom create and edit capability for the MyScheme modular input, and then enable it for the admin and power roles, do the following:
$SPLUNK_HOME/etc/apps/<app_name>/default/authorize.conf
[capability::edit_modinput_MyScheme] [role_admin] edit_modinput_MyScheme = enabled [role_power] edit_modinput_MyScheme = enabled
For more information on roles and capabilities, refer to:
- About defining roles and capabilities in the Securing Splunk Enterprise manual
- authorize.conf spec file in the Configuration File Reference
Set up streaming | Create a custom user interface |
This documentation applies to the following versions of Splunk® Enterprise: 7.0.0, 7.0.1, 7.0.2, 7.0.3, 7.0.4, 7.0.5, 7.0.6, 7.0.7, 7.0.8, 7.0.9, 7.0.10, 7.0.11, 7.0.13, 7.1.0, 7.1.1, 7.1.2, 7.1.3, 7.1.4, 7.1.5, 7.1.6, 7.1.7, 7.1.8, 7.1.9, 7.1.10, 7.2.0, 7.2.1, 7.2.2, 7.2.3, 7.2.4, 7.2.5, 7.2.6, 7.2.7, 7.2.8, 7.2.9, 7.2.10, 7.3.0, 7.3.1, 7.3.2, 7.3.3, 7.3.4, 7.3.5, 7.3.6, 7.3.7, 7.3.8, 7.3.9, 8.0.0, 8.0.1, 8.0.2, 8.0.3, 8.0.4, 8.0.5, 8.0.6, 8.0.7, 8.0.8, 8.0.9, 8.0.10, 8.1.0, 8.1.1, 8.1.2, 8.1.3, 8.1.4, 8.1.5, 8.1.6, 8.1.7, 8.1.8, 8.1.9, 8.1.11, 8.2.0, 8.2.1, 8.2.2, 8.2.3, 8.2.4, 8.2.5, 8.2.6, 8.2.7, 8.2.8, 8.2.9, 8.2.10, 8.2.11, 8.2.12, 9.0.0, 9.0.1, 9.0.2, 9.0.3, 9.0.4, 9.0.5, 9.0.6, 9.0.7, 9.0.8, 9.0.9, 9.0.10, 9.1.0, 9.1.1, 9.1.2, 9.1.3, 9.1.4, 9.1.5, 9.1.6, 9.1.7, 9.2.0, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.3.0, 9.3.1, 9.3.2, 8.1.10, 8.1.12, 8.1.13, 8.1.14
Feedback submitted, thanks!