Date filed Issue number Description
2019-09-09 SII-5486 Email settings link from alert modal is wrong, VictorOps settings link from alert modal is missing
2019-07-01 SII-4834 Power users can't write to the infra_alerts index.

Workaround:
Manually enable power users to write to the infra_alerts index.
2019-06-28 SII-4832, SII-4831 libcurl4 is incompatible with the write_splunk collectd plugin. This affects Ubuntu 18.04.

Workaround:
Replace libcurl4 with libcurl3.
2019-06-04 SII-4558 "No results found" for CPU, Memory, Disk, Network Splunk App for Infrastructure Overview Dashboard

Workaround:
Upgrade to Splunk 7.2.x.
2019-05-23 SII-4475 From the Add Data tab, if you switch back and forth between the Linux/Unix and Mac OS X tab, the install location of the data collection agents may be for the incorrect operating system.
2019-05-23 SII-4476 From the Add Data tab, if you select a new operating system and then go back to the previous one, the selected log and metrics sources may not be accurate. Your log and metrics settings persist in the script but not the user interface.
2019-05-15 SII-4390 The sc_admin role cannot create a HEC token on the em_metrics index.
2019-04-22 SII-4065 When creating an alert, the alert threshold slider may not adjust correctly when you enter a value.
2019-04-02 SII-3907 If you return to view the Group Analysis Workspace for a group after you delete it, the page does not stop attempting to load.
2019-04-02 SII-3913, MAW-2560 When you create an alert, the metric_filter field may not contain any dimensions until you edit the alert.
2019-03-27 SII-3893 Collection intervals for Windows and Linux OS metrics.
2019-02-22 SII-3710 The Splunk Add-on for Windows is not compatible with the Splunk App for Infrastructure.

Workaround:
To use the Splunk Add-on for Windows and the Splunk App for Infrastructure together, see The Splunk Add-on for Windows and Splunk App for Infrastructure are not compatible in the Administer Splunk App for Infrastructure guide.
2018-09-21 SII-2924 The Entity Overview does not properly display metrics values.

Splunk platform issues that impact Splunk App for Infrastructure compatibility

Date resolved Issue number Description
2019-03-07 SPL-167347, 165968 Frequent searches with outputlookup may trigger highly increased KV Store storage usage or in some cases crash of the mongod process. If you are experiencing this issue, upgrade your Splunk software:
  • Splunk Enterprise to version 7.2.5 or later
  • Splunk Cloud to version 7.2.6
Last modified on 03 October, 2019
Fixed issues for Splunk App for Infrastructure   Third-party Software for Splunk App for Infrastructure

This documentation applies to the following versions of Splunk® App for Infrastructure (Legacy): 1.3.1


Was this topic useful?







You must be logged into splunk.com in order to post comments. Log in now.

Please try to keep this discussion focused on the content covered in this documentation topic. If you have a more general question about Splunk functionality or are experiencing a difficulty with Splunk, consider posting a question to Splunkbase Answers.

0 out of 1000 Characters