Independent streamfwd (HEC) tests - TCP/UDP aggregation

This page provides performance test results for the streamfwd binary sending data to indexers using HTTP Event Collector (HEC) and TCP/UDP aggregate configuration. For detailed test environment and configuration information, see Splunk Stream test environments in this manual.

Note: splunkd CPU % and Memory MB performance metrics do not apply to streamfwd when sending data to indexers using HEC.

HTTP 100K response test results

Stats 8Mbps 64Mbps 256Mbps 512Mbps 1Gbps 2Gbps 3Gbps 4Gbps 5Gbps 6Gbps 7Gbps 8Gbps 9Gbps 10Gbps
CPU% (streamfwd) 8 12 24 36 56 90 120 148 169 186 211 239 266 297
Memory MB (streamfwd) 154 156 159 163 170 203 206 208 205 203 227 273 289 305
Events/sec 26 145 587 1171 2285 4608 6907 9161 11435 13742 15991 18334 20636 22904
Drop Rate % 0 0 0 0 0 0 0 0 0 0 0 0 0 0


HTTP 25K response test results

Stats 8Mbps 64Mbps 256Mbps 512Mbps 1Gbps 2Gbps 3Gbps 4Gbps 5Gbps 6Gbps 7Gbps 8Gbps 9Gbps 10Gbps
CPU% (streamfwd) 9 17 40 59 91 136 182 245 297 363 414 246 206 204
Memory MB (streamfwd) 156 160 162 165 172 192 192 198 265 266 306 3881 3999 4367
Events/sec 76 565 2302 4598 8987 17952 26940 35926 44927 53865 62941 27804 14764 16098
Drop Rate % 0 0 0 0 0 0 0 0 0 0 0 0 0 0


HTTPS 100K response test results

Stats 8Mbps 64Mbps 256Mbps 512Mbps 1Gbps 2Gbps 3Gbps 4Gbps
CPU% (streamfwd) 9 25 55 89 125 227 337 403
Memory MB (streamfwd) 217 232 247 262 329 452 532 879
Events/sec 0 72 136 247 463 911 1363 1823
Drop Rate % 0 0 0 0 0 0 0 0


HTTPS 25K response test results

Stats 8Mbps 64Mbps 256Mbps 512Mbps 1Gbps 2Gbps 3Gbps 4Gbps
CPU% (streamfwd) 9 25 55 89 126 226 341 407
Memory MB (streamfwd) 164 230 243 258 305 430 475 897
Events/sec 0 84 136 248 467 918 1353 1825
Drop Rate % 0 0 0 0 0 0 0 0


Enterprise Datacenter

Stats 8Mbps 64Mbps 256Mbps 512Mbps 1Gbps 2Gbps 3Gbps 5Gbps 4Gbps 6Gbps 7Gbps 8Gbps 9Gbps 10Gbps
CPU% (streamfwd) 12 37 90 141 251 245 244 309 274 353 345 352 357 364
Memory MB (streamfwd) 159 243 495 753 1227 3023 3024 3024 3024 3071 3081 3116 3155 3187
Events/sec 289 2155 8352 16121 30706 21052 16035 15777 16259 16542 15170 14850 13496 13159
Drop Rate % 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Last modified on 08 March, 2017
Independent streamfwd (HEC) tests - TCP/UDP raw events   Flow collector performance test results