Configure the collection interval for the Splunk Add-on for EMC VNX

The Splunk Add-on for EMC VNX uses a local collection scheduling engine that you can configure through the ta_vnx_collection.conf file. This configuration controls data collection intervals for each supported metric type. By default, it has the following default collection intervals (in seconds).

   [default]
   vnx_file_inventory_interval = 3600
   vnx_file_sys_performance_interval = 120
   vnx_file_nfs_performance_interval = 120
   vnx_file_cifs_performance_interval = 120
   vnx_block_inventory_interval = 3600
   vnx_block_performance_interval = 120
   vnx_block_status_interval = 300

Copy default/ta_vnx_collection.conf to local/ta_vnx_collection.conf, update the desired values, and restart splunkd to modify collection behavior. Decreasing collection intervals will increase data granularity, but will generate more load for the VNX system.

Important: Do not change values in default/ta_vnx_collection.conf.

PREVIOUS
Configure the modular input for the Splunk Add-on for EMC VNX
  NEXT
Troubleshoot the Splunk Add-on for EMC VNX

This documentation applies to the following versions of Splunk® Supported Add-ons: released


Was this documentation topic helpful?

Enter your email address, and someone from the documentation team will respond to you:

Please provide your comments here. Ask a question or make a suggestion.

You must be logged into splunk.com in order to post comments. Log in now.

Please try to keep this discussion focused on the content covered in this documentation topic. If you have a more general question about Splunk functionality or are experiencing a difficulty with Splunk, consider posting a question to Splunkbase Answers.

0 out of 1000 Characters