Publication date | Defect number | Description |
---|---|---|
2016-12-13 | TAB-1798 | App Pre-Certification validation reports erroneous failures for add-ons, specifically errors mentioning missing itsi*.conf or deep_dive_drilldowns.conf files. |
2016-11-29 | TAB-1736 | Conflicts can occur with Python libraries when installing Add-on Builder with other apps. |
2016-11-08 | TAB-1631 | The Download Package button is grayed out on the Validate & Package page. This issue occurs when you place a file in your add-on directory to which you do not have sufficient access permission. |
2016-10-12 | TAB-1545 | Alert action doesn't write events correctly without the CIM add-on installed. |
2016-10-12 | TAB-1543 | Modular inputs do not pass App Certification. |
2016-10-12 | TAB-1517 | Add-on Builder repeatedly requests a restart if the modular input code contains an error. |
2016-10-12 | TAB-1508 | Can't create data inputs with the name of a deleted data input until restarting Splunk Enterprise. |
2016-10-12 | TAB-1502 | The sourcetype and eventtype defined in an alert action is not managed by Add-on Builder, which might cause conflicts in some rare cases. |
2016-10-12 | TAB-1500 | Could not open multiple add-ons in multiple tabs. |
2016-10-12 | TAB-1438 | The Add-on Setup Parameters tab is not displayed in Splunk Enterprise 6.4. |
2016-10-12 | TAB-1388 | In Create Alert Actions, the helper.writeevents function does not clean up added events. |
2016-10-12 | TAB-1374 | Field validation failure prevents the Create Alert Action wizard from going to the next page. |
2016-10-12 | TAB-1371 | Indicator numbers and bar charts are designed to grow dynamically in Validation. |
2016-10-12 | TAB-1355 | HTTP 500 error occurs when testing a shell command input with Splunk Enterprise installed in Windows. |
2016-10-12 | TAB-1354 | HTML is not displayed with beautified format. |
2016-10-12 | TAB-1337 | Align the Python code template and Python helper functions for adaptive response actions and data inputs. |
2016-10-12 | TAB-1330 | Some lookups are referred to by prebuilt panels or saved searches rather than transforms.conf. |
2016-10-12 | TAB-1302 | Add-on setup parameters that are in progress are not synchronized with the production setup page under Manage Apps. |
2016-10-12 | TAB-1263 | The Best Practice check for duplicated stanza headers or fields will pass even if duplication exists. |
2016-10-12 | TAB-1257 | To access one of multiple user accounts on a setup page, you still needs to manually add a option in inputs/alerts to refer to one of the accounts. |
2016-10-12 | TAB-1235 | Percentage of "Validation Status" is not accurate. |
2016-10-12 | TAB-1164 | There is no Terminate button for the alert action code test. |
2016-08-16 | TAB-1152 | Field extraction hangs at 80% for some samples when the raw event size is very large or there are too many (100+) groups after clustering. |
2016-10-12 | TAB-1094 | Changing visible-related functions when editing an add-on won't trigger the prompt to restart Splunk Enterprise. |
2016-10-12 | TAB-1048 | "Monitoring Console" does not appear in the Settings menu for Add-on Builder. |